CEL-LPH120 Low-pressure mercury lamp light source

Model:CEL-LPH120

Place of Origin:Beijing

Brief introduction:120W ultra-strong ultraviolet low-pressure mercury lamp, the main output wavelength is 254nm, 185nm uses a serpentine lamp, the irradiation area is 128*128mm, can realize downward irradiation and side irradiation.

Contact now

ModelCEL-LPH120-254      CEL-LPH120-185

120W ultra-strong ultraviolet low-pressure mercury lamp, the main output wavelength is 254nm, 185nm uses a serpentine lamp, the irradiation area is 128*128mm, can realize downward irradiation and side irradiation.



Technical advantages

1.The main wavelengths of 254nm and 185nm can be selected at will;

2.120W high-power low-pressure solid-state mercury lamp;

3. Realize the stable output of strong light in the ultraviolet region, 50mw/cm2;

4.Illumination area has realized 128mm*128mm, large area uniform illumination;

5. It can realize downward irradiation and side irradiation;

6. The long life of low-pressure mercury lamps can be achieved, up to 5000 hours;

7. Integrated light source system, compact design, 288mm*180mm*100mm.

8.High emissivity low pressure mercury lamp with solid amalgam;

9.The amalgam is consolidated with the inner wall of quartz and can be placed horizontally or vertically;

10.Ultra-high radiation density and long life;

11.High temperature resistance, 105 can still run stably for a long time, does not affect the radiation intensity at all;

12.The illuminance distribution is uniform, and the snake-shaped turning point adopts wind bracing to eliminate the weak point phenomenon of illuminance caused by the "shrinking neck" of the turning point of general products;

13.Power: 120W;

14. Material: low hydroxyl synthetic quartz;

15. Lamp current: 1200mA;


Characteristics of low pressure mercury lamp

1)Solid amalgam high emissivity low pressure mercury lamp (serpentine)

2)The amalgam is consolidated with the inner wall of quartz and can be placed horizontally or vertically.

3)Ultra-high radiation density, ultra-long life

4)Resistant to high temperature, 105 ℃ can still operate stably for a long time, and does not affect the radiation intensity at all.

5)The illuminance distribution is uniform, and the serpentine bending point adopts wind support pressure, which eliminates the illuminance weakness caused by the "necking" of the general product bending point.

6)Power:120W

7)MaterialSynthesis of quartz with low hydroxyl groups

8)Lamp current

9)Length:Face shape, outer dimension about 140mm x 140mm, double pin

10)Startup form:Need to preheat start-up


Product configuration

1) One LPH120 main unit 【including one 254nm (or 185nm)lamp】;

2) 4 projection support rods;

3) A set of power cord, manual, certificate, acceptance slip, warranty certificate

Optional: strong ultraviolet light output, it is recommended to purchase CEL-LB70 protective box